教員業績データベース |
|
論文種別 | 総説 |
言語種別 | 英語 |
査読の有無 | 査読あり |
表題 | The resonance® metallic ureteral stent in the treatment of malignant ureteral obstruction: a prospective observational study. |
掲載誌名 | 正式名:BMC urology 略 称:BMC Urol ISSNコード:1471249014712490 |
掲載区分 | 国外 |
巻・号・頁 | 19(1),pp.137 |
著者・共著者 | Miyazaki Jun, Onozawa Mizuki, Takahashi Satoshi, Maekawa Yuka, Yasuda Mitsuru, Wada Koichiro, Maeda Yuji, Masaki Takuro, Yamaguchi Akito, Suzuki Masahiko, Sakai Yasuyuki, Kimura Tomokazu, Takai Manabu, Seike Kensaku, Hashimoto Takahiko, Yamamoto Shingo |
発行年月 | 2019/12 |
概要 | BACKGROUND:To study the outcomes and experiences of using metallic stents in treating patients with malignant ureteral obstruction (MUO), we examined the effects of metallic ureteral stenting using the Cook Resonance® stent in the treatment of MUO.METHODS:All patients who had a Resonance metallic stent inserted between April 2015 and March 2018 at one of multiple facilities were prospectively observed with a 1-year follow-up. The primary outcome was the patency rate of the metallic ureteral stent. The secondary outcomes included the complications (e.g., infectionand fever).RESULTS:Although stent insertion was attempted in 50 patients, the stent could not be inserted as a ureteral stent in three patients due to severe ureteral stricture, and one ureteral cancer patient was excluded from the analysis. |
DOI | 10.1186/s12894-019-0569-y |
PMID | 31881875 |